2020 NEC 551.71(F) : GFCI at new RV Pedestal, inspectors want 50A and ...
Nov 1, 2024 · Now we have an earth pedestal combo with a meter (20A, 30A, 50A built in) we want to put in with a direct bored conduit from a transformer or H.H. The inspector is saying we need to swap …
Grounding Electrode for RV Pedestal??? | Information by Electrical ...
Feb 16, 2023 · 1st ISSUE Is a grounding electrode required for an RV pedestal that has a 50 amp breaker and receptacle with a 20 amp receptacle and breaker? If my understanding is correct it is not …
rv pedestal in mobile home park | Information by Electrical ...
Apr 5, 2024 · Customer wants to hook up a rv pedestal in mobile home park. poco is about 50ft away i wanted to put a 100amp feed through panel under the meter at the poco pole. Run 1/o, 1/o, 1/o, 1/o, …
RV pedestals and the Tap Rule - Mike Holt's Forum
Jun 7, 2020 · I'm designing my first RV Park. The pedestals my customer wants are offered by more than one manufacturer and are very similar. They have a 2P50A, a 1P30A, and a 1P20A breaker …
Bonding neutral at a pedestal for RV parks | Information by Electrical ...
Apr 14, 2024 · I have five to 200 amp disconnects each disconnect the neutral and ground are bonded and these are the service disconnects and then they feed individual 30 amp pedestals in RV Park …
ground rods needed at sub panel ? | Information by Electrical ...
May 18, 2022 · A customer has installed a 200 amp meter - disconnect combo at a utility pole and then trenched to a barn with a 200 amp sub panel. They installed ground rods at the pedestal but not at …
Remote pedestal feed to the house | Information by Electrical ...
Oct 7, 2018 · I have a remote pedestal where my meter base is located. Also on the pedestal is my 200 amp breaker for my house. The feed then runs to a disconnect on the side of the house, then feeds …
Adding a pedestal seat to a wood floor | Michigan Sportsman Forum
Mar 9, 2025 · I have a 16’ polar Kraft that I want to add a pedestal seat to the rear of the boat. The floor is 1/2” or 5/8” plywood….i don’t remember off hand. I can locate the metal supports so I know where …
Pedestal Placement Clearances | Information by Electrical Professionals ...
Nov 1, 2004 · Re: Pedestal Placement Clearances Bryan, I have a homeowner who will not stop complaining to my local government until the competitors cable LE ped is moved out of the easement …
230.71 and RV parks | Information by Electrical Professionals for ...
Mar 16, 2023 · Each pedestal is its own structure technically, but 225 will allow up to 6 switches. 230 only applied to service equipment, but if the pedestals were suitable as service equipment they …